Start/Produkte/Vakuum Relais / Schalter

WVS-Technology / Produktinformationen

JPK-2/015 / ...

Zur Produktübersicht ↗
Vakuum Relais

Serie JPK-2/015 - JPK-2/020

www.wvs-tech.de - Vakuum Relais - Serie JPK-2/015 - JPK-2/020 www.wvs-tech.de - Vakuum Relais - Serie JPK-2/015 - JPK-2/020 - Skizze seitenansicht www.wvs-tech.de - Vakuum Relais - Serie JPK-2/015 - JPK-2/020 - Skizze draufsicht
Contact Parameter
Code 4015 4016 4017 4018 4001 4019 4020
Specification No JPK-2/015 JPK-2/016 JPK-2/017 JPK-2/018 JPK-2/001 JPK-2/019 JPK-2/020
Contact Configuration 1Z
Test Voltage
(DC or AC 50Hz Peak)kV
15
Reated Working
Voltage (Peak)
kV
DC or AC 50H 12
AC 2,5 MHz 10
AC 16 MHz 8
AC 32 MHz 5
Rated Current
(Carry, RMS)
A
DC or AC 50Hz 50
AC 2,5 MHz 30
AC 16 MHz 17,5
AC 32 MHz 10
Contact Resistance (Max.)Ω 0,012
Capacitance
pF
Between
Open Contacts
0,5
Between Contact
and Envelope
1
Coil Parameter
Rated Coil Voltage (DC) V 6 12 18 24 26,5 48 115
DC Coil Resistance Ω ±10% 17 72,5 130 180 270 615 5400
Pull-in Voltage (25&degC, Max.) V 4 9 11 15 16 30 70
Dropout Voltage
(Over range of Temp.) V
---- 0,5~5,8 ---- ---- 1~10 ---- 2~40
Operate Time (Max.) ms 18 18 18 18 18 18 18
Release Time (Max.) ms 9 9 9 9 9 9 9
Insulation Property
Insulation Resitance, Min. MΩ 1000
Dielectric
Withstand
Voltage
(AC 50Hz RMS)
kV
Between Open
Contacts
15
Between Contact
and Envelope
15
Between Coil
and Envelope
0,5
Ambient Adaptability
Range of Temp. &degC -55~125
Shock. (11 ms 1/2 Sine)
m/s2(g)
490(50)
HF Vibration
m/s2(g), Hz
98(10), 55~500
Mounting Form Optional
Weight and Life
Weight (g) 85
Life (Mechanical cycles) 106 1

zurück zur Auswahl